PDMS Design Error Message lists

This chapter PDMS Design Error Message lists error messages specific to DESIGN. These messages have a message number beginning with 61. Any other messages that may be output are not described here as they are not specific to DESIGN.

Note that in the following element_identifier denotes an element name or (for unnamed elements) an element reference number. The latter is a ‘system’ number which is assigned automatically whenever an element is created.

(61:1) Unable to calculate the orientation
(61:2) element_identifier is not a piping or a hanger component or has not been positioned oriented or selected.
(61:3) element_identifier is not a branch or piping component
(61:4) element_identifier is not a hanger or hanger component
(61:5) Unable to position element_identifier
(61:6) element_identifier does not have a position
(61:7) Unable to orientate element_identifier
(61:8) element_identifier does not have an orientation
(61:9) Unable to set the head position of element_identifier
(61:10) Unable to set the tail position of element_identifier
(61:11) Unable to set the head direction of element_identifier
(61:12) Unable to set the tail direction of element_identifier
(61:13) Trying to connect element_identifier to itself
(61:14) Unable to set the head reference of element_identifier
(61:15) Unable to set the tail reference of element_identifier
(61:16) Current element does not have a head or a tail attribute
(61:17) Default orientation only available for piping and hanger components.
(61:18) Default orientation cannot be found. Previous element either not positioned and oriented or not selected.
(61:19) Direction undefined for towards origin of current element
(61:20) Current element type unsuitable for DIRECTION command
(61:21) SPREF can only be selected for a piping or hanger component
(61:22) LSTUBE can only be selected for a piping component
(61:23) HSTUBE can only be selected for a BRANCH
(61:24) LSROD can only be selected for a hanger component
(61:25) HSROD can only be selected for a HANGER
(61:26) TUBE can only be selected for a BRANCH or a piping component
(61:27) ROD can only be selected for a HANGER or a hanger component
(61:28) Only BRANCHs, HANGERs, and piping and hanger components can be selected
(61:29) element_identifier is not a SPEC
(61:30) element_identifier is not a SPCOM
(61:31) Cannot find SPCOM name
(61:32) Appending name to specification name gives a name of more than 50 characters.
(61:33) Angle attributes can only be given values between -180 and +180 degrees.
(61:34) Degenerate orientation specified
(61:35) Pins cannot be used for connecting piping or hanger components
(61:36) Reconnecting element_identifier
(61:37) Connection to element_identifier is invalid (HREF / TREF do not point back to nozzle )
(61:38) element_identifier is locked, reconnection fails
(61:39) element_identifier is in a read-only database, reconnection fails
(61:40) Plane parallel to movement direction
(61:41) Default movement direction only available for piping and hanger components.
(61:42) Default movement direction not available. Previous element either not positioned and oriented or not selected.
(61:43) ARRIVE / LEAVE ppoint cannot be determined. Current element has probably not been selected.
(61:44) Default movement origin cannot be determined.
(61:45) BOP and TOP can only be used with piping and hanger components.
(61:46) DIRECTION command only operates on ppoints of the current element
(61:47) Bad DIRECTION – zero degree angle specified
(61:48) Point set does not allow variable angle. Angle is unchanged, direction is in correct plane.
(61:49) Unable to achieve specified direction – probably due to unconventional pointset
(61:50) Pin numbers must be in the range 1 to 10
(61:51) Unable to position pin integer
(61:52) Unable to orientate pin integer
(61:53) Unable to copy the marker
(61:75) element_identifier is not a branch, reconnect fails
(61:76) Connection to a database that is not open, reconnection fails
(61:77) Cannot find P-point 1 – Nozzle catalogue reference probably not set
(61:78) Reconnect not allowed at WORLD or GPWL level
(61:79) element_identifier cannot own nozzles
(61:80) Cannot access SPCOM from which to reselect
(61:81) To position the HEAD / TAIL of a branch or hanger use POS / MOVE PH / PT / HH / HT …
(61:82) BOP / TOP cannot be used on a HEAD / TAIL that has not been positioned
(61:83) Default clearance is only available for piping or hanger components
(61:84) Shear attributes can only be given values between -89 and +89 degrees.
(61:85) element_identifier cannot be flipped – it does not have ARRIVE and LEAVE attributes.
(61:86) Warning – Angle is greater than maximum specified in SPREF
(61:87) Warning – Angle is less than minimum specified in SPREF
(61:88) SPREF not found or unset
(61:89) element_identifier does not have a Local-axes attribute
(61:120) Too many views shown
(61:121) Form name too word for screen
(61:122) Unable to set form gadget value or gadget not found
(61:123) Form name not found
(61:125) Gadget name not found
(61:126) Item invalid as contents of view
(61:127) Form name already shown
(61:128) Form name may not be hidden
(61:129) Cannot open Recreate file
(61:130) File error while restoring data – RESTORE aborted
(61:131) File error while restoring data – please exit from module and reenter
(61:132) Unable to RESTORE – databases modified since module state SAVEd
(61:133) Unable to SAVE – cannot access SAVE file
(61:134) Unable to SAVE – SAVE file already in use
(61:135) Unable to RESTORE – SAVE file already in use
(61:136) Unable to RESTORE Рcannot access SAVE file
(61:137) Unable to RESTORE Рcannot find SAVE file
(61:138) Unable to RESTORE – current database files are not those which were in use when module state SAVEd
(61:139) Unable to RESTORE – module version number/screen size/font size is not the same as SAVE file
(61:140) Do you wish to save changes?
(61:150) Only piping components, nozzles and equipments can be dragged
(61:151) element_identifier is connected to element_identifier which is in a read only database. This connection will be broken by drag.
(61:152) element_identifier has a connection to an unknown element. This connection will be broken by drag.
(61:153) element_identifier is locked, drag aborted
(61:154) The connection from element_identifier to element_identifier will be broken by drag.
(61:155) Attachment points can only be dragged if they have been positioned and oriented
(61:160) Spec is not set up correctly for CHOOSE command
(61:161) element_identifier is not a piping component
(61:162) SPEC does not contain word elements
(61:163) SPEC does not contain correct bore structure for CHOOSE
(61:164) SPEC does not contain elements matching given criteria
(61:165) Previous component, element_identifier, has zero bore
(61:166) Unforced Connections are word
(61:167) Forced Connections are word
(61:168) Connections are OFF
(61:169) Warning – Requested bore value does not match current bore word
(61:175) HOFFSET must be positive ( not zero )
(61:190) Fatal error detected by Graphics Package forcing a return to MONITOR module
(61:191) Are your databases to be updated with the changes made this session (Y or N)
(61:192) Fatal error detected by SPLASH forcing a return to MONITOR module
(61:193) WARNING – System storage area value % full. Remove items from drawlist to avoid fatal error.
(61:194) WARNING – Graphics storage area value % full.
(61:199) Cannot access directory name
(61:201) No more than 20 items can be given to AUTO
(61:206) XR and YR values must be in the range 0 to 1.0.
(61:207) Specified region is too narrow.
(61:208) Illegal autolimits produced. ( Does it have any primitives? )
(61:209) Mix values for colours are percentages ( 0 – 100 )
(61:211) Only colours 1 to integer may be assigned to pens
(61:220) Failed to connect.
(61:221) Cannot calculate default orientation.
(61:225) Usable colours are system colours plus user colours 1 to integer
(61:226) Autolimits may only be set for graphic views, Please select a graphics view and retry
(61:230) Error reading from plotfile ..
(61:231) Unrecognised code in plotfile
(61:272) Already using file – name for alpha output
(61:273) Cannot open alpha output file
(61:274) No alpha output file in use.
(61:275) Already using log file – name
(61:276) Cannot open log file
(61:278) No log file in use.
(61:303) Direction cannot be calculated between two design points with the same position – UP is assumed
(61:304) Position cannot be calculated as lines are parallel – first point given is assumed
(61:305) Position cannot be calculated as line and plane are parallel – first point given is assumed
(61:306) Angle cannot be calculated as two points are coincident – zero assumed
(61:307) Only significant and drawable elements can be tagged by type
(61:351) The WORLD and GPWLs cannot be added / removed. SITEs can only be added using ‘ADD SITE’ in a setup context.
(61:355) No more than ten elements can be added at one time
(61:357) element_identifier is not a SITE
(61:358) Only SITEs or ZONEs can be specified for ADD WITHIN. The default is all sites in the multiple database.
(61:461) Hit radius must be at least 1mm.
(61:462) Hit radius must be no more than 100mm.
(61:463) Working grid must be at least 1mm.
(61:471) Cursor abandoned
(61:495) Form name may not be changed
(61:499) F&M: Cannot swap parent of a blocking form
(61:561) Workstation screen is not available, using TTY
(61:564) Cursor input not allowed on alpha device
(61:565) Point entered is not in a suitable view
(61:599) Forms may not be updated
(61:800) Reference DETAIL not set
(61:820) SKEY not set
(61:830) SKEY TSFL is used with generic type TEE, not TRAP
(61:840) SKEY element_identifier not known. Assumed to be user defined